Redundant, Hot Swappable Components
76
Redundant, Hot Swappable Components
Two RAID controllers or copper/optical I/O modules,
removable from the rear.
Two power supplies, removable from the rear.
Two advanced cooling modules, removable from the rear.
Two loop resiliency and SES modules (LS), removable from
the front.
Up to 14 disk drives, removable from the front.
Two independent AC power inlets.
Maximum Cable Lengths
Copper: 30 meters (equalized cable) from server or switch/hub
to enclosure.
Optical: 500 meters using a copper/optical adapter from server
or switch/hub to enclosure.
10 meters (equalized cable) between successive enclosures.
Physical Dimensions
Deskside Enclosure Height: 20 inches (50.8cm)
Width: 9 inches (22.9cm)
Depth: 20 inches (50.8cm)
Weight: 75 lbs (34kg) maximum
Rack Enclosure Height: 5.22 inches (13.3cm)
Width: 15.5 inches (44.5cm)
Depth: 20 inches (50.8cm)
Weight: 75 lbs (34kg) maximum